Application
OA3 fiber optic cable is designed for laying through rivers crossings, navigable and non-navigable rivers, deep-water lakes and reservoirs, bayous, direct burial in soil (including frozen deformated soil), ducts, conduits, collectors and tunnels, bridges and overpasses.
Cable design
- Optical fibers (or fiber bundles) of different colors.
- Central polymer tube filled by waterblocking compound.
- Galvanized steel wire armoring, including high-strength wires with tensile load no less than 1670 MPa.
- Waterblocking tape.
- Aluminum tape with polymer coating.
- Inner PE sheath.
- Galvanized steel wire armoring, including high-strength wires with tensile load no less than 1670 MPa.
- Outer PE sheath.
Armouring free space is filled with waterblocking compound.
Specifications
- Fiber count – up to 64;
- Static tensile strength – from 60 kN to 250 kN;*
- Crush resistance – from 1.0 kN/cm to 3.0 kN/cm;*
- Impact resistance – 50 J;
- Allowed bending radius – from 280 mm to 550 mm;
- Excessive hydrostatic pressure resistance – at least 2 MPa;
- Cable diameter – from 14,0 mm to 27.5 mm;
- Cable weight – from 380 kg/km to 2015 kg/km;
- Outer PE sheath insulation resistance (circuit “armor – land (water)”) – 4000 MOm*km;
- Cable length on a drum – up to 12 km.
Diameter, weight and allowed radius of bending are reference values.
* – customer can choose values in ranges provided