OP3 cable

op2

Application

OP3 fiber optical cable is designed for direct burial in soil (including frozen deformated soil), laying on bridges and overpasses. Laying in ducts, conduits, collectors and tunnels is also possible

Cable design

  1. Optical fibers (or fiber bundles) of different colors.
  2. Central polymer tube filled by waterblocking compound.
  3. Galvanized steel wire armoring, including hight-strength wires with tensile load no less than 1670 MPa.
  1. Inner PE sheath.
  2. Galvanized steel wire armoring, including hight-strength wires with tensile load no less than 1670 MPa.
  3. Outer PE sheath.

Armouring free space is filled with waterblocking compound.

Specifications

  • Fiber count – up to 64;
  • Static tensile strength – from 60 kN to 250 kN;*
  • Crush resistance – from 0,4 kN/cm to 1,5 kN/cm;*
  • Impact resistance – 50 J;
  • Allowed bending radius – from 280 mm to 550 mm;
  • Cable diameter – from 14,0 mm to 27,5 mm;
  • Cable weight – from 380 kg/km to 2010 kg/km;
  • Outer PE sheath insulation resistance (circuit “armor – land (water)”) – 4000 MOm*km;
  • Cable length on a drum – up to 12 km.

Diameter, weight and bending radius are reference values.

* – customer can choose values in ranges provided